220
Chapter 9
Metal ion sources for the electroplating from non-aqueous solutions are
selected from suitable inorganic or organic compounds with a good
solubility and a high conductivity. The nature of the dissolved salt and
structure of cations and anions of non-aqueous electrolytes influences more
significantly the electrocrystallization, than is the case for aqueous solutions.
This effect is attributed to an increased complexation and specific action
between dissolved compound and solvents. In this way the nature of the
organic solvent and electrolyte determine the possibility of metal deposition.
Advantages of non-aqueous electrolytes for plating purposes include a
larger voltage window of solvent stability, very low or no reactivity with
substrates, formation of variety of complex ions in solutions and dissolved
salts do not hydrolyze.
39
A larger window allows a greater flexibility in
selecting cell-operating voltages. No reactivity of non-aqueous electrolytes
with substrate makes possible to plate metals such as for example uranium
with nickel or zinc
38
, which react with aqueous types of electrolytes.
Disadvantages of non-aqueous electrolytes are associated with toxicity,
flammability, explosion, low electrical conductivity, sensitivity to water and
a relatively high cost. Electrodeposition of metals from organic solutions
requires specially designed systems, which must be protected from oxygen,
carbon dioxide and moisture.
In terms of solvents, non-aqueous electrolytes, used in electrodeposition
of metals and alloys may be divided into two large groups: organic-solvent
based and inorganic-solvent based. Examples of organic solvents are
benzene, toluene, ethyl pyridinium bromide, diethyl ether, ethyl benzene,
tetrahydrofuran, etc.. The number of inorganic solvents used for plating
purposes is significantly smaller. The inorganic solvents include liquid
ammonia, thyonil chloride and sulfuryl chloride.
Metals depositable from non-aqueous systems can be divided into two
large groups.
38
In the first group are listed metals, which cannot be
deposited from aqueous solutions, i.e. metals of the first group of the
periodic table (Li, Na, K), metals of the second group (Be, Mg, Ca), metals
of the third group (Al) and metals of the fourth group (Ge, Ti, Zr). To this
group are also added metals of the fifth and the sixth groups of the periodic
table (i.e. V, Nb, Mo and W). Note that metals such as Mo and W are listed
into the first group, although they can be deposited from the aqueous
solutions, but not in the pure state. Metals such as Mo and W are readily
deposited from aqueous solutions, however only in the presence of iron
group of metals (i.e. Ni, Co, etc., see the section related to the electrode-
position of alloys).
In the second group of metals, which can be plated from non-aqueous
solutions are listed metals usually deposited from aqueous systems (i.e., Cu,
Zn, Co, Sn, Ni etc.). Although these metals are commonly deposited from