Hydraulic Transients and DynamicEffects
- 123 -
When the powerhouse is equipped with reaction turbines, both the upstream and
downstream water columns must be analysed, in order to avoid excessive
overpressure at penstock and at powerhouse or even water column rupture at
draft tubes. A classic solution to minimise hydraulic transients or to reduce the
total length of the hydraulic conveyance system under waterhammer action
consists to insert a surge tank as near the powerplant as possible. However, this
solution can not be advisable, because it can be a very costly structure and can
cause significant environmental impacts for a small hydropower plant. Thus, a
good estimation of the maximum transient pressure without any special
protection device is very important.
7.5- Special protection devices
7.5.1- Introduction
The protection devices to control transient pressures due to turbine operation
can act by different ways: by supplying or removing water, or by flow energy
accumulation or dissipation. Typical protection devices for small hydropower
plants are among others (RAMOS, 1995):
- surge tanks;
- air vessels;
- synchronised valves, automatic discharge valves or pressure relief
valves;
- flywheels.
The mathematical formulation applied in computational modelling and analysis
of protection components of a hydropower scheme are also presented. The
selection of the best solution for the protection devices depends upon the
hydraulic characteristics and topography that can influence the conveyance
system profile of the hydraulic circuit. Also important is the simulation of the
integrated system in order to know the best and correct dynamic response and the
influence of different devices always kept up with an economical comparison
study. The more suitable protection devices to small hydropower plants are next
presented, based on a simplified mathematical formulation and a brief
explanation of its performance.
For abnormal conditions (emergency or exceptional operating conditions)
creating potential excessive overpressures during a full load rejection of very fast
flow stoppage due to a safety valve closure a pressure fusible section. This