Ladder
269
SI 143 Write/Read to LC Source (MI or SI) & Length:
SI 144
SI 145
Write: Address or Value
SI 146 Read to PLC
SI 147 Read to MI vector
Commands Quick Reference List
To run a command, store the command number into SI140 after storing the parameters in SIs 141-147 as
required by the command.
The Help topics for each command contain details.
Calibration
Name # SI 140 Parameters Store to Description
Calibration point #, LC #,
location
SI 141
Status indication SI 142
Weight value location, direct or
MI, 1-2 registers according to
resolution
SI 143
Calibrate point
8448
Contain either weight value or MI
link address, according to SI 143
SIs 144,
145
Matches a Raw Value with a Weight value.
These points are used to linearize the input
value.
Calibration point #, LC #,
location
SI 141
Status indication SI 142
Location of Raw or Weight values
written to LC, direct or MI, 2-4
registers according to resolution
SI 143
Edit Calibrated
Point
8449
Contain either Raw or Weight
value or MI link address,
according to SI 143
SIs 144,
145
Writes new Raw Value and Weight values for
a calibrated point.
Calibration point #, LC #,
location
SI 141
Status indication SI 142
Read Calibration
Point
8705
Contain either Raw or Weight
value location, direct or MI, 2-4
registers according to resolution
SIs 146,
147
Read current raw and weight values of a
Calibration Point from LC, write values into
PLC registers.
Calibration point #, LC #,
location
SI 141
Delete Calibration
Point
8193
Status indication SI 142
Delete a Calibration Point from the LC.
Calibration point #, LC #,
location
SI 141
Save Calibration
9219
Status indication SI 142
Burns calibration, calibrated points, tare, zero,
and input range into the module's EEPROM.
1, LC #, location SI 141
Clear Calibration
9219
Status indication SI 142
Deletes a specific Loadcell's calibration from
module's memory, not EEPROM.
Clear/Save Calibration use same command #;
different value stored into SI 141.
LC location SI 141
Disable all other
Loadcells
9228
Status indication SI 142
Number & location of the LC that will not be
disabled.
Enable all
9228 1, LC #, location SI 141 Enables all LCs on module, Disable/Enable