UNIT 43 Heat-Pump Controls 399
2. If the unit is set in the heating mode and thermostat contact H
1
closes, what is the normal
action of the unit?
A. The heat strips, indoor fan motor, outdoor fan motor, and compressor turn on.
B. The indoor fan motor, outdoor fan motor, and compressor turn on.
C. The heat strips and indoor fan motor turns on.
D. The heat strips, outdoor fan motor, indoor fan motor, compressor, and reversing valve
turn on.
3. Assume that cooling thermostat C
0
is closed and C
1
is open. What is the normal operating
sequence of the unit?
A. The indoor fan motor, outdoor fan motor, and compressor turn on.
B. Only the indoor fan motor turns on.
C. The indoor fan motor, outdoor fan motor, reversing valve, and compressor turn on.
D. The reversing valve turns on.
4. Assume that fuses FL
1
and FL
2
connected to strip heaters HTR-1 and HTR-2 are blown.
Now assume that thermostat HT
1
closes and starts the heat pump compressor, but the
outside temperature is too low to permit the heat pump to suf ciently heat the dwelling
and thermostat H
2
closes also. What will be the action of the unit?
A. The compressor will continue to run, but the heat strips will not activate because they
are staged and must operate in proper sequence.
B. The heat pump compressor stops operating because thermostat H
2
prevents both the
compressor and heat strips from being turned on at the same time.
C. The compressor continues to operate and after some period of time sequencer 1 will
time out and turn on sequencer 2 energizing heating elements HTR-3 and HTR-4. If
enough time elapses, sequencer 2 will time out and turn on sequencer 3 which ener-
gizes heating elements HTR-5 and HTR-6.
D. The compressor will eventually be disconnected from the line due to high pressure
because the inside blower cannot operate in the heating mode if the rst bank of strip
heaters fail to operate.
5. The schematic shows a small lamp connected between terminals C and L on the thermo-
stat. What is this lamp used to indicate?
A. The compressor is in operation.
B. The compressor motor has failed.
C. The unit is in the defrost mode.
D. The thermostat has been set for emergency heat.