Support denisty
– calculated with tip to face distance 0.979÷1.17 MPa
– Calculated without tip to face distance 1.07÷1.28 MPa
Advance forces
– shield (for 25 MPa) 0.357 MN
(for 30 MPa) 0.429 MN
– AFC (for 25 MPa) 0.161 MN
(for 30 MPa) 0.194 MN
Max. operating pressures
– on floor 2.96 MPa
– on roof 1.28 MPa
Controls systems E-H system
Supply pressure min 25÷30 MPa
Hydraulic liquid oil – in – water emulsion
HFAE or HFAS class
Total mass 18 200 kg
TECHNICAL PARAMETERS FOR HYDRAULIC ROOF SUPPORT
System of operation “one web back”
Range of height
– max 3.4 m
– min 1.4 m
Operation range 1.6÷3.3 m
Approved slopes of longwall
– longitudinal do 35°
– transversal +/- 15°
Support centre 1.5 m
Number of legs 2 pcs
Capacity per leg
– at yeild (for 47 MPa) 3.779 MN
– at set (for 25 MPa) 2.01 MN
(for 30 MPa) 2.57 MN
Advance rate 0.8 MPa