THE ATMOSPHERIC AND VACUUM CRUDE DISTILLATION UNITS 137
Heat out
With lighter product vapors rising from the top PA tray.
Total steam from flash zone and side stream strippers below top PA tray.
Liquid pumparound leaving the tower.
Liquid product draw off plus strip out leaving to stripper (if applicable).
Liquid overflow from the PA draw-off tray.
The pumparound duty in Btu/hr.
In these items the only unknown is the enthalpy and therefore the temperature of
the vapor leaving the top pumparound tray. Equate Heat in = Heat out to solve the
unknown.
Step 5. With the duty of the pumparound section in Btu/hr and the temperatures in
and out now known, the pumparound section can be treated as a heat exchanger.
The area of heat transfer will be the total tray areas of the section, and the heat
transfer coefficient in terms of Btu/hr/sqft/
◦
F is given in Figure 3.12.
Step 6. The area is now calculated from the heat transfer equation;
Q = UA t
m
where
Q = Heat transferred in Btu/hr
U =The overall heat transfer coefficient in Btu/hr/sqft/
◦
F
A = Heat transfer area in sqft.
t
m
=Log mean temperature difference in
◦
F.
Step 7. The number of trays required will be determined from the tray or tower di-
ameter calculation provided by a future calculation to determine the tower dimens-
ions.
Calculating the main tower dimensions
Having established the number of trays and the relative location of pumparound and
side stream draw off, the overall dimensions of the tower can be calculated. Note: The
number of trays allocated to the pumparound sections may be revised based on the tray
or tower diameter calculation for those sections. This will not affect the tray loading
calculations which will determine the tray diameters. The calculation to determine the
tower diameter(s) is based on the vapor/liquid loading on each section of the tower.
This loading is based on a series of heat balances to determine this traffic to and from
the critical trays. These critical trays are:
r
The top stripping tray of the residue stripping section (below the flash zone)
r
The bottom side stream and pumparound draw-off tray
r
The next pumparound draw-off (and the side stream if applicable) tray