Alstom MiCOM P125, P126, P127 Series - Directional/Non-Directional Relays
Short Technical Description. Publication P12y/EN BR/Cc.
Alstom, Electronic Edition, 2003. — 16 pages.
Краткое техническое описание на английском языке.
The MiCOM Directional/non-Directional overcurrent Relays provide flexible and reliable integration of protection, control, monitoring and measurement functions.
Extensive functionality provides complete protection and control for a wide range of overhead lines and underground cables, from distribution to transmission voltage levels, capacitors bank, generators and transformer generator schemes.
Направленные/ненаправленные токовые реле MiCOM обеспечивают гибкую и надежную интеграцию функций защиты, управления, контроля и измерений.
Расширение функций обеспечивает полную защиту и управление широкого диапазона воздушных и кабельных линий разных уровней напряжения, конденсаторных батарей, генераторов и блоков генератор-трансформатор.
Table of Contents:
Introduction.
Protection.
Control.
Measurement.
Monitoring.
Communications.
Diagnostic.
User friendly interface.
Software support.
Models available and functionalities.
Application.
Protection and control functions (P125, P126, P127).

Phase directional overcurrent (P127).
Phase overcurrent (P126).
Earth fault directional overcurrent (P125, P126, P127).
Wattmetric (P125, P126, P127).
Undercurrent (P126, P127).
Broken conductor (P126, P127).
Negative phase sequence overcurrent (P126, P127).
Thermal overload (P126, P127).
Undervoltage (P127).
Overvoltage (P127).
Residual overvoltage (P125, P126, P127).
Blocking logic (P125, P126, P127).
Selective relay scheme logic (P126, P127).
Cold load pick up (P126, P127).
Setting groups.
Programmable inputs and outputs (P125, P126, P127).
Latching of the outputs relay (P125, P126, P127).
Circuit breaker failure protection (P126, P127).
Autoreclose (P126, P127).
Monitoring and measurement.
Circuit Breaker monitoring (P126, P127).
Trip Circuit Supervision (TCS) (P126, P127).
Measurements.
Event records (P126, P127).
Disturbance records (P126, P127).
Fault records (P126, P127).
User Interface.
Front display and menus.
Dedicated LEDs.
Programmable LEDs.
Keypad.
Local and remote communication.
Remote communication.
Local communications.
Diagnostic.
Hardware.
Case.
Battery box.
Wiring.
Technical specifications.
Inputs.
Burdens.
Thermal withstand.
Accuracy.
CT requirement.
VT requirement.
HMI.
Directional/non-directional phase overcurrent settings.
Directional/non-directional earth fault settings.
Directional/non directional overcurrent and directional/non directional earth fault time setting.
Earth fault wattmetric thresholds Pe/Ie cos.
IeCos thresholds.
Pe/Iecos characteristic angle.
Under current thresholds.
Negative sequence current thresholds.
Thermal replica thresholds.
Under voltage thresholds.
Over voltage thresholds.
Zero sequence voltage thresholds.
Cold load pick up.
Auto reclose (79).
AND logical gates.
Auxiliary timers.
Circuit breaker control (50BF).
Trip circuit supervision.
Contacts.
Housing.
High voltage withstand.
Electrical environment.
Environmental withstand.
EMC compliance.
Product safety.
MiCOM P125, P126, P127 outline description.
Ordering code.
Mechanical Drawings.

Micom P125.
Micom P126 and P127.